{"id":10176,"date":"2025-01-13T17:39:56","date_gmt":"2025-01-13T14:39:56","guid":{"rendered":"https:\/\/www.kiracmetal.com\/en\/?page_id=10176"},"modified":"2025-01-13T17:39:59","modified_gmt":"2025-01-13T14:39:59","slug":"cable-trays-general-information-and-installation-guide","status":"publish","type":"page","link":"https:\/\/www.kiracmetal.com\/en\/cable-trays-general-information-and-installation-guide\/","title":{"rendered":"CABLE TRAYS GENERAL INFORMATION AND INSTALLATION GUIDE"},"content":{"rendered":"<p>[vc_row][vc_column][vc_separator border_width=&#8221;2&#8243;][vc_column_text]<\/p>\n<h4>1- CABLE TRAYS GENERAL INFORMATION AND INSTALLATION GUIDE<\/h4>\n<hr \/>\n<p>General information of K\u0131ra\u00e7 Metal Cable Trays and installation guide are arranged in accordance with IEC 61537<br \/>\nstandards and this document has been prepared for benefit of cable tray users.<\/p>\n<p><strong>WARNING:<\/strong> Do not use a cable tray as a walkway, ladder or support for people. Cable tray is a mechanical<br \/>\nsupport system for cables and raceways. Using cable trays as walkways can cause personal injury and also<br \/>\ndamage cable tray and installed cables.<br \/>\nPerformances of cable tray systems are dependent on its proper installation, including supports and cables.<br \/>\nNeglecting installation and maintenance guidelines may lead to personal injury as well as damage to property.<br \/>\nInstallation and maintenance of cable tray systems shall be conducted only by qualified personnel and responsible<br \/>\npersons should be trained properly. During installation, the necessary safety practices shall be implemented and<br \/>\nprotective equipment such as insulated rubber gloves, hard hat, safety glasses or face shields, dust mask should<br \/>\nbe used.<br \/>\nCable management systems should be selected in accordance with required loading capacity. Therefore, cable<br \/>\nloads planned to be added to the system in the future shall also be considered while selecting a cable tray or<br \/>\ncable tray support system.<\/p>\n<h4><strong>A) GENERAL INFORMATION<\/strong><\/h4>\n<hr \/>\n<h5>Receiving and Unloading<\/h5>\n<p>Cable tray is generally bundled and shipped via motor freight, except for export shipments that could be loaded in<br \/>\ncontainers. Accessories and small components are boxed and often skidded. During receiving and unloading of<br \/>\ncable trays, some cautions should be considered as shown in the pictures below.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium aligncenter\" src=\"https:\/\/www.kiracmetal.com\/en\/wp-content\/uploads\/2025\/01\/Ekran-g\u00f6r\u00fcnt\u00fcs\u00fc-2025-01-13-165544-1.png\" width=\"917\" height=\"232\" \/><\/p>\n<p>If the vehicle isn\u2019t suitable for uploading by forklift as indicated in the picture below, it should be hand unloaded.<br \/>\nTo prevent damage to cable trays, never pull cable tray from truck trailer by chaining to bottom rung and dragging<br \/>\nout of trailer. If hand unloaded, workers should wear gloves and steel toed footwear.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"https:\/\/www.kiracmetal.com\/en\/wp-content\/uploads\/2025\/01\/Ekran-g\u00f6r\u00fcnt\u00fcs\u00fc-2025-01-13-172747.png\" width=\"1837\" height=\"640\" \/><\/p>\n<h5>Storage<\/h5>\n<p>Hot dip galvanized and stainless-steel cable trays can be stored without cover but should be loosely stacked,<br \/>\nelevated off the ground and ventilated to prevent storage stain. If appearance is important, cable tray should be<br \/>\nstored indoors to prevent water or other foreign materials from staining or adhering to cable tray.[\/vc_column_text][vc_separator border_width=&#8221;2&#8243;][vc_column_text]<\/p>\n<h4><span style=\"color: #000000;\">B) INSTALLATION<\/span><\/h4>\n<hr \/>\n<p>Cable tray systems are to be installed so they are accessible. If possible 300mm minimum should be left above or<br \/>\nbetween installed systems to allow for cable installation and maintenance. There should be electrical continuity<br \/>\nconnection between each cable tray and cable tray system shall be bonded to building steel and earth at least<br \/>\nevery 18 meters.<br \/>\nSupports for cable trays should provide strength and working load capabilities sufficient to meet the load requirement of the cable tray system. Consideration should be given to the loads associated with future cable additions or<br \/>\nany other additional loads applied to the cable tray system or the cable trays support system.<\/p>\n<h4>Installation of Cable Trays<\/h4>\n<p><span style=\"color: #000000;\">Kablo kanal\u0131 sistemleri eri\u0219ilebilir \u0219ekilde kurulmal\u0131d\u0131r. Kablo d\u00f6\u015fenebilmesi ve bak\u0131m\u0131 i\u00e7in, e\u011fer m\u00fcmk\u00fcnse yukar\u0131dan ve di\u011fer montajlanm\u0131\u015f sistemlerden yakla\u015f\u0131k 300mm bo\u015fluk b\u0131rak\u0131lmal\u0131d\u0131r. Her bir kablo kanal\u0131 aras\u0131nda elektriksel s\u00fcreklilik ba\u011flant\u0131s\u0131 bulunmal\u0131 ve kablo kanal\u0131 sistemi en az 18 metrede bir yap\u0131 \u00e7eli\u011fine ba\u011flanarak topraklanmal\u0131d\u0131r.<\/span><br \/>\n<span style=\"color: #000000;\">Kablo ta\u015f\u0131ma sistemleri, kablo kanal\u0131 sisteminin y\u00fckleme gereksinimini kar\u0219\u0131lamaya yetecek mukavemete sahip olmal\u0131d\u0131r. Gelecekteki kablo eklemeleriyle ilgili y\u00fckler ve kablo kanal\u0131 sistemine veya ta\u015f\u0131ma sistemine uygulanan di\u011fer ek y\u00fckler de dikkate al\u0131nmal\u0131d\u0131r.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>WARNING:<\/strong> Do not cut or drill structural building members (e.g. I-beams) without approval by the general contractor. In order to install the cable tray supports, first find the required elevation from the floor to the bottom of the<br \/>\ncable tray and establish a level line with a laser or a nylon string.<\/span><\/p>\n<h4>Installation of Accessories<\/h4>\n<p>Bending radius of accessories are determined depending on the bending radius of installed cables. Manufacturers<br \/>\ndefine minimum bending radius for each cable. Radius of accessory should be equal or greater than min. bending<br \/>\nradius of the largest cable. When many cables are installed in the same cable tray, the biggest bending radius<br \/>\nshould be considered to make easier installation. Support distance that should be placed after bending is shown in<br \/>\nthe drawings below. Supports should be placed maximum 600mm away from all outputs of the bending.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium aligncenter\" src=\"https:\/\/www.kiracmetal.com\/en\/wp-content\/uploads\/2025\/01\/Ekran-g\u00f6r\u00fcnt\u00fcs\u00fc-2025-01-13-173409.png\" width=\"1453\" height=\"772\" \/><\/p>\n<p><strong>Installation of splice plate (IEC 61537 7.3j)\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u00a0<\/strong><\/p>\n<p style=\"text-align: left;\">Planning the locations of splice plate connectors is difficult, however it is important to be aware of this fact.The least beneficial location of splice plate connectors is the midpoint of the gap or the immediate upper part of the support. Installing splice place connectors to these two points should be avoided particularly at the end gaps. If possible, splice plate connector should be installed to the \u00bc of the length of the gap between the supports.\u00a0<strong><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.kiracmetal.com\/en\/wp-content\/uploads\/2025\/01\/Ekran-g\u00f6r\u00fcnt\u00fcs\u00fc-2025-01-13-173625.png\" width=\"434\" height=\"243\" \/><\/strong><\/p>\n<p><strong>Separator Requirement<\/strong><\/p>\n<p>Separators are used to separate cable systems such as when cables above or below 600 volt installed in the same<br \/>\ncable tray. However, when MC type cables are installed in the same cable tray with cables rated 600 volt or less<br \/>\nno separator is required. Separators should be made of the same material as the cable tray. When ordering<br \/>\nseparator, the height must match the loading depth of the cable tray into which it is being installed.<\/p>\n<p><strong>Future Expansion Requirement<\/strong><\/p>\n<p>In the future many cables can be added on the existing cable tray system. When selecting a cable tray, future<br \/>\nexpansion requirement should be considered, and allowance should be made for additional fill area and load<br \/>\ncapacity. A minimum of %30 expansion allowance is recommended.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_separator border_width=&#8221;2&#8243;][vc_column_text] 1- CABLE TRAYS GENERAL INFORMATION AND INSTALLATION GUIDE General information of K\u0131ra\u00e7 Metal Cable Trays and installation guide are arranged in accordance with IEC 61537 standards and this document has been prepared for benefit of cable tray users. WARNING: Do not use a cable tray as a walkway, ladder or support for people. &hellip; <a href=\"https:\/\/www.kiracmetal.com\/en\/cable-trays-general-information-and-installation-guide\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">CABLE TRAYS GENERAL INFORMATION AND INSTALLATION GUIDE<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-10176","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/pages\/10176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/comments?post=10176"}],"version-history":[{"count":1,"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/pages\/10176\/revisions"}],"predecessor-version":[{"id":10189,"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/pages\/10176\/revisions\/10189"}],"wp:attachment":[{"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/media?parent=10176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}