{"id":10198,"date":"2025-01-14T09:12:34","date_gmt":"2025-01-14T06:12:34","guid":{"rendered":"https:\/\/www.kiracmetal.com\/en\/?page_id=10198"},"modified":"2025-01-14T09:12:34","modified_gmt":"2025-01-14T06:12:34","slug":"mechanical-properties-of-cable-tray","status":"publish","type":"page","link":"https:\/\/www.kiracmetal.com\/en\/mechanical-properties-of-cable-tray\/","title":{"rendered":"MECHANICAL PROPERTIES OF CABLE TRAY"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<\/p>\n<h4>MECHANICAL PROPERTIES OF CABLE TRAY<\/h4>\n<h5>A) SAFE WORKING LOAD<\/h5>\n<p>When in use, the cable management system has to support the weight of the cables and other complementary<br \/>\nproducts. The products safe working load test values according to IEC 61537 help adapt the best installation<br \/>\nconfiguration<\/p>\n<p>Safe working load (SWL) is the maximum load which can be applied safely during normal cable management use.<br \/>\nWhile testing, gradually increasing loads are applied to the cable management system. This uniformly distributed<br \/>\nload is expressed in daN\/m .<\/p>\n<p>The safe working load obtained guarantees:<br \/>\n\u2022 A maximum longitudinal deflection of 1\/100th of the span (example: 20 mm deflection for a distance between<br \/>\nsupports of 2000 mm)<br \/>\n\u2022 A maximum horizontal deflection of 1\/20th of the cable tray width (example: 10 mm deflection for a cable tray<br \/>\nwidth of 200 mm)<br \/>\n\u2022 A safety coefficient of 1.7.<\/p>\n<p>There are three types of tests: They are mainly distinguished by the location of the coupling in the span<\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>Type 1:<\/strong> A connector shall be located in the middle of the first span. Associated mounting recommendation: this<br \/>\nis the most restrictive configuration, which can offer a guarantee of safe loads in the installation without any<br \/>\nconditions.<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-9460\" src=\"https:\/\/www.kiracmetal.com\/wp-content\/uploads\/2021\/11\/cizim1-300x40.png\" alt=\"\" width=\"300\" height=\"40\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>Type 2:<\/strong> : A connector shall be located in the middle of the second span. Associated mounting recommendation:<br \/>\nto guarantee safe loads, the installation should not contain a coupling in an end span.<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-9462\" src=\"https:\/\/www.kiracmetal.com\/wp-content\/uploads\/2021\/11\/cizim2-300x40.png\" alt=\"\" width=\"300\" height=\"40\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>Type 3:<\/strong> The position of the connector is fixed, the length of the tested cable tray must be a multiple of the span.<br \/>\nAssociated mounting recommendation: the installation should comply with the manufacturer\u2019s recommended<br \/>\ncoupling location.<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-9463\" src=\"https:\/\/www.kiracmetal.com\/wp-content\/uploads\/2021\/11\/cizim3-300x48.png\" alt=\"\" width=\"300\" height=\"48\" \/><\/span><\/p>\n<p>NEMA VE-1 is a cable management standard which has evolved in parallel with IEC 61537 but drafted by a North<br \/>\nAmerican electrical committee. The standard specifies the manufacturing requirements for metal cable trays and<br \/>\nprovides load\/span class designations. It also stipulates requirements and test methods for cable tray systems<br \/>\nwith aim to declare the required load capacity.The test is conducted on the cable management system uniformly<br \/>\nloaded between two supports.<\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-9465\" src=\"https:\/\/www.kiracmetal.com\/wp-content\/uploads\/2021\/11\/cizim4-300x90.png\" alt=\"\" width=\"300\" height=\"90\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Destructive method:\u00a0<\/strong> This involves continuing until the system collapses. The load chosen for the SWL is then<br \/>\nthe collapse load divided by a safety factor of 1.5.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Support Span:<\/strong> Strength of a cable tray system is largely determined by the strength of its side rails. The<br \/>\nstrength of a side rail is proportionate to the distance between the supports on which it is installed, commonly<br \/>\nreferred to as \u2018support span\u2019. Therefore, strength of a cable tray system can be changed by modifying support<br \/>\nspan. The support span length should be equal or less than uncoupled straight section lengths to ensure that no<br \/>\nmore than one splice is placed between the supports<\/span><\/p>\n<h5><span style=\"color: #000000;\">B) DEFLECTION<\/span><\/h5>\n<p>All profiles deflect when a load is imposed. The deflection of cable tray is related to applied load, support span,<br \/>\nsize and material of beam and load. Deflection tests are carried out according to IEC 61537.<\/p>\n<h5><span style=\"color: #000000;\">C) IMPOSED LOADS<\/span><\/h5>\n<p>Imposed loads include wind, ice and snow. The effects of imposed loads will vary from one installation to another<br \/>\nand further advice relating to the specific influences of each should be sought at the design stage. The following<br \/>\ninformation on imposed loads is given as a general guide only.<\/p>\n<p><span style=\"color: #000000;\"><strong>Snow loads:<\/strong> The additional design load from snowfall should be determined using the building codes that apply<br \/>\nfor each installation<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Ice loads:<\/strong> The additional load design due to the ice is determined by the following formula:<br \/>\n<strong>Wi = W x Ti x Di\/106<\/strong><br \/>\nWhere:<br \/>\nWi = ice load (kg\/m)<br \/>\nW = width of the tray (mm)<br \/>\nTi = maximum ice thickness (mm)<br \/>\nDi = 913 kg\/m\u00b3 \u2013 ice density<\/span><\/p>\n<p>Ice thickness will vary depending on installation location. A value of \u00bd\u201d (12.7mm) can be used as a<br \/>\nconservative standard.<\/p>\n<p><strong>Wind Loads:<\/strong> The additional loading to be considered is the effect of the impact pressure vertical to the side rail.<br \/>\nThis loading is determined by the following formula:<br \/>\n<strong>Wp = 0.00256 x V2 x H\/12<\/strong><br \/>\nWhere:<br \/>\nWp = loading due to the wind (lbs\/linear foot)<br \/>\nV = wind velocity (mph)<br \/>\nH = height of the side rail (inch)<\/p>\n<p><strong>Seismic loads:<\/strong> It is now known that cable tray systems can withstand stronger earthquakes than previously<br \/>\nthought. The tray itself and the support material are highly ductile, and the cables moving within the tray tend to<br \/>\ndissipate energy. However, if you have specific seismic specifications for selected cable tray, please consult K\u0131ra\u00e7<br \/>\nMetal team to ensure your specifications are met.<\/p>\n<h5><span style=\"color: #000000;\">D) THERMAL EXPANSION AND CONTRACTION\u00a0<\/span><\/h5>\n<p>A cable tray system may be affected by thermal expansion and contraction, which must be taken into account<br \/>\nduring installation. To determine the number of expansion splice plates you need, decide the length of the straight<br \/>\ncable tray runs and the total difference between the minimum winter and maximum summer temperatures. To<br \/>\nfunction properly, expansion splice plates require accurate gap settings between trays. To find the gap (see Figure<br \/>\n1).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"https:\/\/www.kiracmetal.com\/en\/wp-content\/uploads\/2025\/01\/Ekran-g\u00f6r\u00fcnt\u00fcs\u00fc-2025-01-14-091012.png\" width=\"927\" height=\"642\" \/><\/p>\n<p>To plot the gap setting:<br \/>\n\u2022 Locate the lowest metal temperature on min. temperature line.<br \/>\n\u2022 Locate the highest metal temperature on max. temperature line.<br \/>\n\u2022 Connect these two points.<br \/>\n\u2022 Locate installation temperature and plot to high\/low line.<br \/>\n\u2022 Drop plot to gap setting.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"https:\/\/www.kiracmetal.com\/en\/wp-content\/uploads\/2025\/01\/Ekran-g\u00f6r\u00fcnt\u00fcs\u00fc-2025-01-14-091137.png\" width=\"1062\" height=\"742\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] MECHANICAL PROPERTIES OF CABLE TRAY A) SAFE WORKING LOAD When in use, the cable management system has to support the weight of the cables and other complementary products. The products safe working load test values according to IEC 61537 help adapt the best installation configuration Safe working load (SWL) is the maximum load which &hellip; <a href=\"https:\/\/www.kiracmetal.com\/en\/mechanical-properties-of-cable-tray\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">MECHANICAL PROPERTIES OF CABLE TRAY<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-10198","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/pages\/10198","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/comments?post=10198"}],"version-history":[{"count":1,"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/pages\/10198\/revisions"}],"predecessor-version":[{"id":10201,"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/pages\/10198\/revisions\/10201"}],"wp:attachment":[{"href":"https:\/\/www.kiracmetal.com\/en\/wp-json\/wp\/v2\/media?parent=10198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}